Quasi-static Tests of Pile-cap Connections for the Prestressed Spun Concrete Square Piles

Song Er-xiang
DOI: https://doi.org/10.3969/j.issn.1000-0844.2013.02.0246
2013-01-01
Abstract:Quasi-static tests of six full-scale prestressed spun concrete square piles-cap connections were conducted to investigate the influence of 4 parameters on the seismic behavior of the connection.The results and findings indicate:①With axial load larger than 1 700 kN,failures governed by concrete compression take place in the connected part of the piles due to small eccentricity.②Axial load increases the loading capacity for the connection but on the other hand decreases its deformation capacity.The connection shows considerable deformation capacity under axial load of 1 700 kN.③Connection under diagonal loading condition is statically weaker,while showing better deformation capacity.④With a 50 mm dowel depth into the cap,the connection functions well and is capable of larger deformation.But the corresponding equivalent viscous damping coefficient is lower at failure.
What problem does this paper attempt to address?