Experimental study on axial compression behavior of composite reinforced concrete prefabricated square piles

XU Quanbiao,CHEN Gang,HE Jingfeng,GONG Shunfeng,XIAO Zhibin
DOI: https://doi.org/10.14006/j.jzjgxb.2017.10.020
2017-01-01
Abstract:The composite reinforced concrete prefabricated square piles were developed and tests were conducted on the axial compression behavior of nine specimens for three types of commonly-used piles to investigate the differences between partially prestressed and non-prestressed concrete prefabricated square piles in terms of compressive bearing capacity,deformation capacity and failure characteristics.The experimental results of the ultimate compressive bearing capacity were compared with the calculated values from different specification formulas.The test results show that global failure and local failure are two axial compression failure modes of composite reinforced concrete prefabricated square piles.For the specimens of the same pile type,the compressive stiffness is almost the same and has no significant degradation before failure.The experimental values of the ultimate compressive bearing capacity for composite reinforced concrete prefabricated square piles can only meet the requirement of the GB 50007-2011'code for design of building foundation',and are generally smaller than those of non-prestressed concrete prefabricated square piles.The axial compression bearing capacity for composite reinforced concrete prefabricated square piles is recommended to be calculated by the code for design of building foundation.