Design of PPS Self-Calibration High-Precision Frequency Meter Based on STM32 Single Chip Microcomputer
Xiangjie Kong,Jinbao Wang,Zihui Wei,Peng Dong
DOI: https://doi.org/10.1109/EIECT60552.2023.10442747
2023-11-17
Abstract:In order to solve the problem of low precision and high cost of traditional frequency meter, this paper proposes a design method of high precision digital frequency meter based on STM32H750 series microcomputer. This method can effectively solve the problem of counting error of ±1 words in the cycle measurement method and the frequency measurement method, improve the accuracy and reduce the cost. By continuously correcting the PPS (pulse per second) signal received from the synchronous satellite, the disadvantage of the traditional measurement method is supplemented to a certain extent. Compared with traditional frequency meters, this method fully utilizes the advantages of high-speed and accurate microcontroller, and has the characteristics of small size, fast speed, and high accuracy. The design scheme of the frequency meter given in this design is not only feasible, but also simple in design, low in cost and wide in measurable frequency band, which greatly reduces the design cost and implementation complexity.
Computer Science,Engineering