A Scale Factor Calibration Method for MEMS Resonant Accelerometers Based on Virtual Accelerations

Zhaoyang Zhai,Xingyin Xiong,Liangbo Ma,Zheng Wang,Kunfeng Wang,Bowen Wang,Mingjiang Zhang,Xudong Zou
DOI: https://doi.org/10.3390/mi14071408
2023-07-12
Abstract:This paper presents a scale factor calibration method based on virtual accelerations generated by electrostatic force. This method uses a series of voltage signals to simulate the inertial forces caused by the acceleration input, rather than frequent and laborious calibrations with high-precision instruments. The error transfer model of this method is systematically analyzed, and the geometrical parameters of this novel micromachined resonant accelerometer (MRA) are optimized. The experimental results demonstrate that, referring to the traditional earth's gravitational field tumble calibration method, the error of the scale factor calibration is 0.46% within ±1 g by using our method. Moreover, the scale factor is compensated by virtual accelerations. After compensation, the maximum temperature drift of the scale factor decreases from 2.46 Hz/g to 1.02 Hz/g, with a temperature range from 40 °C to 80 °C.
What problem does this paper attempt to address?