Effect of region of interest on ADC and interobserver variability in thyroid nodules

Xiang Zhou,Chao Ma,Zhi Wang,Jia-Ling Liu,Yuan-Peng Rui,Yue-Hua Li,Yi-Feng Peng
DOI: https://doi.org/10.1186/s12880-019-0357-x
2019-07-12
Abstract:Background: To determine the effect of region of interest (ROI) on tumor's apparent diffusion coefficient (ADC) and interobserver variability in thyroid nodules. Methods: Thirty-three individuals with 45 pathologically-confirmed thyroid nodules were assessed by preoperative diffusion-weighted imaging (DWI) with b values of 0 and 400 s/mm2, respectively. Two readers evaluated the ADC values of lesions based on three ROI techniques: whole-volume, single-slice and small solid-sample groups. Interobserver variability was analyzed for all ROI techniques, and the mean ADCs of benign and cancerous thyroid nodules were compared. Results: For the mean ADCs of non-cancerous thyroid nodules, average differences and limits of agreement (LOAs) between readers were 0.00 [- 0.17-0.17] × 10- 3 mm2/s for whole-volume ROI (ICC = 0.967), 0.00 [- 0.26-0.26] × 10- 3 mm2/s for single-slice ROI (ICC = 0.932) and - 0.02 [- 0.38-0.41] × 10- 3 mm2/s for small solid-sample ROI (ICC = 0.823). For the mean ADCs of cancerous thyroid nodules, average differences and LOAs between readers were - 0.05 [- 0.23-0.13] × 10- 3 mm2/s (ICC = 0.885), 0.01 [- 0.23-0.25] × 10- 3 mm2/s (ICC = 0.839) and - 0.07 [- 0.52-0.39] × 10- 3 mm2/s (ICC = 0.579) for the three ROI methods, respectively. The mean ADC values were more scattered in the small solid-sample ROI group in comparison with the whole-volume and single-slice groups, in noncancerous and cancerous specimens. Of all three ROI techniques, whole-volume ROI-determined ADC had the highest combined sensitivity (80.0%), specificity (88.3%) and Youden index (0.683), with a cut-off of 1.84 × 10- 3 mm2/s. Conclusions: The ROI method overtly affects ADC measurements in benign and cancerous thyroid nodules. Small solid-sample ROI yielded the worst interobserver variability of average ADC measurements.
What problem does this paper attempt to address?