Comparative analysis of the image quality and diagnostic performance of the zooming technique with diffusion-weighted imaging using different b-values for thyroid papillary carcinomas and benign nodules

Liling Jiang,Jiao Chen,Yong Tan,Jian Wu,Junbin Zhang,Daihong Liu,Jiuquan Zhang
DOI: https://doi.org/10.3389/fonc.2024.1241776
IF: 4.7
2024-05-07
Frontiers in Oncology
Abstract:Objective: To compare image quality and diagnostic performance using different b-values for the zooming technique with diffusion-weighted imaging (ZOOMit-DWI) in thyroid nodules Materials and methods: A total of 51 benign thyroid nodules and 50 thyroid papillary carcinomas were included. ZOOMit-DWI was performed with b-values of 0, 500, 1000, 1500 and 2000 s/mm 2 . The sharpness was evaluated as subjective index. The signal intensity ratio (SIR), signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) were measured as objective indices. Pairwise comparisons were performed among the different b-value groups using the Friedman test. A receiver operating characteristic curve of the ADC value was used to evaluate diagnostic performance. The DeLong test was used to compare diagnostic effectiveness among the different b-value groups Results: In both the papillary carcinoma group ( P = 0.670) and the benign nodule group ( P = 0.185), the sharpness of nodules was similar between b-values of 1000 s/mm 2 and 1500 s/mm 2 . In the papillary carcinoma group, the SIR nodule was statistically higher in DWI images with a b-value of 1500 s/mm 2 than in DWI images with b-values of 500 s/mm 2 ( P = 0.004), 1000 s/mm 2 ( P = 0.002), and 2000 s/mm 2 ( P = 0.003). When the b-values were 1500 s/mm 2 ( P = 0.008) and 2000 s/mm 2 ( P = 0.009), the SIR nodule significantly differed between the papillary carcinoma group and the benign nodule group. When b = 500 s/mm 2 , the ADC had an AUC of 0.888. When b = 1000 s/mm 2 , the ADC had an AUC of 0.881. When b = 1500 s/mm 2 , the ADC had an AUC of 0.896. When b = 2000 s/mm 2 , the ADC had an AUC of 0.871. The DeLong test showed comparable diagnostic effectiveness among the different b-value groups except for between b-values of 2000 s/mm 2 and 1500 s/mm 2 , with a b-value of 2000 s/mm 2 showing lower effectiveness Conclusion: This study suggests that 1500 s/mm 2 may be a suitable b-value to differentiate benign and malignant thyroid nodules in ZOOMit-DWI images, which yielded better image quality
oncology
What problem does this paper attempt to address?