A high-speed, high-resolution Transition Edge Sensor spectrometer for soft X-rays at the Advanced Photon Source

Orlando Quaranta,Don Jensen,Kelsey Morgan,Joel C. Weber,Jessica L. McChesney,Hao Zheng,Tejas Guruswamy,Jonathan Baldwin,Ben Mates,Nathan Ortiz,Johnathon Gard,Doug Bennet,Dan Schmidt,Lisa Gades,Antonino Miceli
2025-01-04
Abstract:This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X- ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.
Instrumentation and Detectors,Superconductivity
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is the current lack of high - performance soft X - ray spectrometers, which limits the potential of Resonant Soft X - ray Scattering (RSXS) technology in studying the electronic and magnetic properties of materials. Specifically, the paper aims to design and develop a high - resolution, high - speed spectrometer based on Transition Edge Sensor (TES) to overcome the limitations of existing technologies. ### Main Problems 1. **Lack of High - Performance Soft X - ray Spectrometers**: - Existing soft X - ray spectrometers have deficiencies in energy resolution, efficiency, and energy range, which limit the application of RSXS technology. 2. **Background Noise and Signal - to - Noise Ratio Problems**: - In RSXS experiments, the emission of core - level fluorescence photons may drown out the resonant signal, causing the detected signal to be masked by background noise. 3. **Experimental Efficiency and Data Acquisition Speed**: - Traditional spectrometers are less efficient in multi - point simultaneous analysis and cannot meet the needs of modern experiments for rapid data acquisition. ### Solutions To solve the above problems, the paper proposes a new TES spectrometer design with the following features: - **High Energy Resolution**: By optimizing the design of TES, it can achieve an energy resolution of about 1 eV, thus effectively distinguishing weak resonant signals from background noise. - **Efficient Data Acquisition**: A microwave multiplex read - out chip (μmux) is adopted, with each channel having a bandwidth of 1 MHz and a total bandwidth of up to about 2 GHz, supporting efficient parallel data acquisition and significantly increasing data throughput. - **Low - Temperature Operating Environment**: To achieve higher energy resolution, an operating temperature of about 90 mK is selected, and a bismuth (Bi) - doped absorption layer is used to improve the detection efficiency while maintaining a low heat capacity without affecting the energy resolution. - **Integration and Compatibility**: A probe head (snout) about 1 meter long is designed to ensure that the instrument can be seamlessly integrated with existing beamline systems in an ultra - high - vacuum environment while maintaining high detection efficiency. ### Summary The goal of this paper is to enhance the capabilities of soft X - ray scattering technology, especially for Resonant Soft X - ray Scattering (RSXS) measurements, by developing a high - performance TES spectrometer. This will help researchers gain a deeper understanding of the microstructure and interactions of complex materials and promote innovation and development in fields ranging from condensed - matter physics to chemical kinetics.