High accuracy, high dynamic range optomechanical accelerometry enabled by dual comb spectroscopy

D. A. Long,J. R. Stroud,B. J. Reschovsky,Y. Bao,F. Zhou,S. M. Bresler,T. W. LeBrun,D. F. Plusquellic,J. J. Gorman
DOI: https://doi.org/10.1063/5.0165582
2023-10-11
Abstract:Cavity optomechanical sensors can offer exceptional sensitivity; however, interrogating the cavity motion with high accuracy and dynamic range has proven to be challenging. Here we employ a dual optical frequency comb spectrometer to readout a microfabricated cavity optomechanical accelerometer, allowing for rapid simultaneous measurements of the cavity's displacement, finesse, and coupling at accelerations up to 24 g (236 m/s$^2$). With this approach, we have achieved a displacement sensitivity of 3 fm/Hz$^{1/2}$, a measurement rate of 100 kHz, and a dynamic range of 3.9 $\times$ 10$^5$ which is the highest we are aware of for a microfabricated cavity optomechanical sensor. In addition, comparisons of our optomechanical sensor coupled directly to a commercial reference accelerometer show agreement at the 0.5% level, a value which is limited by the reference's reported uncertainty. Further, the methods described herein are not limited to accelerometry but rather can be readily applied to nearly any optomechanical sensor where the combination of high speed, dynamic range, and sensitivity is expected to be enabling.
Optics,Quantum Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to improve the measurement accuracy, dynamic range and measurement rate of micromechanical cavity optomechanical accelerometers. Specifically, the main challenge faced by the researchers is how to simultaneously and rapidly measure cavity displacement, fineness and coupling efficiency within a high - precision and wide dynamic range. Traditional methods such as laser - locking techniques can work effectively when the measured frequency offset is small, but their locking bandwidth and tuning range are limited, which severely restricts the dynamic range and measurement rate. Therefore, this paper proposes a method using a dual - optical - frequency - comb spectrometer to read out the micromechanical cavity optomechanical accelerometer, thereby achieving high - precision, high - dynamic - range and high - rate measurements. It is mentioned in the paper that through this method, the researchers achieved the following results: - The displacement sensitivity reached \(2 \text{ fm/Hz}^{1/2}\). - The measurement rate reached 100 kHz. - The dynamic range reached \(7.6\times 10^5\), which is the highest dynamic range among known micromechanical cavity optomechanical sensors. In addition, the paper also shows the comparison results between this optomechanical accelerometer and a commercial reference accelerometer. The two are consistent at the 0.5% level, and this value is limited by the reported uncertainty of the reference accelerometer. These methods are applicable not only to accelerometers, but also to other optomechanical sensors that require high precision, high dynamic range and high sensitivity.