Radio frequency Coulomb blockade thermometry

Florian Blanchet,Yu-Cheng Chang,Bayan Karimi,Joonas T. Peltonen,Jukka P. Pekola
DOI: https://doi.org/10.48550/arXiv.2109.09677
2021-11-29
Abstract:We present a scheme and demonstrate measurements of a Coulomb blockade thermometer (CBT) in a microwave transmission setup. The sensor is embedded in an $LCR$ resonator, where $R$ is determined by the conductance of the junction array of the CBT. A transmission measurement yields a signal that is directly proportional to the conductance of the CBT, thus enabling the calibration-free operation of the thermometer. This is verified by measuring an identical sensor simultaneously in the usual dc setup. The important advantage of the rf measurement is its speed: the whole bias dependence of the CBT conductance can now be measured in a time of about 100\,ms, which is thousand times faster than in a standard dc measurement. The achieved noise equivalent temperature of this first rf primary measurement is about 1 mK/$\sqrt{\rm Hz}$ at the bath temperature $T=200\,$mK.
Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a fast and efficient method for measuring the absolute temperature at extremely low (sub - Kelvin) temperatures. Specifically, the authors proposed and experimentally verified a Coulomb - blocked thermocouple (CBT) based on radio - frequency (rf) transmission measurement. This method can complete the measurement of the conductivity bias - dependence of CBT within about 100 milliseconds, which is thousands of times faster than the traditional direct - current (dc) measurement method. ### Main Problems and Solutions 1. **Limitations of Traditional Measurement Methods**: - The traditional Coulomb - blocked thermocouple (CBT) in standard direct - current or quasi - direct - current measurements requires several minutes to achieve satisfactory accuracy. - This slow measurement speed limits its use in applications that require a fast response. 2. **Proposed Solutions**: - The authors proposed a new scheme based on radio - frequency (rf) transmission measurement, embedding the CBT into an LCR resonant circuit. - With this new method, the conductivity measurement within the entire bias - voltage range can be completed in about 100 milliseconds, greatly increasing the measurement speed. 3. **Technical Implementation**: - The CBT sensor is embedded into an LCR resonant circuit, where the resistance \( R \) is determined by the conductivity of the CBT junction array. - The signal obtained from the radio - frequency transmission measurement has a linear relationship with the conductivity of the CBT, allowing the temperature to be directly deduced from the measurement signal without additional calibration. 4. **Performance Advantages**: - The experimental results show that the noise - equivalent temperature (NET) of this method is approximately 1 mK/\(\sqrt{\text{Hz}}\), achieving high - precision measurement at an ambient temperature of 200 mK. - The measurement time is shortened from several minutes to about 100 milliseconds, increasing the speed by a factor of 1,000. ### Formula Summary - **Conductivity Formula**: \[ G(v)/G_T = 1 - u g(v) - \frac{u^2}{4} [g'(v) h'(v) + g''(v) h(v)] \] where: \[ g(v) = \frac{e v (e v (v - 2) + v + 2)}{(e v - 1)^3}, \quad u = \frac{E_C}{k_B T}, \quad v = \frac{e V}{N k_B T}, \quad h(v) = v \coth\left(\frac{v}{2}\right) \] - **Temperature Calculation Formula**: \[ T = \frac{0.18385 e}{N k_B V_{1/2}} \] and the corrected formula: \[ T = \frac{0.18385 e}{N k_B V_{1/2}} \left(1 + 0.3921 \frac{\Delta G}{G_T}\right)^{-1} \] ### Conclusion By introducing the radio - frequency transmission measurement method, the authors have successfully achieved a fast and efficient Coulomb - blocked thermocouple measurement technique, which is suitable for temperature measurement in extremely low - temperature environments. This method not only significantly improves the measurement speed but also maintains high precision, providing a powerful tool for research in the fields of low - temperature physics and quantum electronics.