Metallic Coulomb Blockade Thermometry down to 10 mK and below

L. Casparis,M. Meschke,D. Maradan,A. C. Clark,C. Scheller,K. K. Schwarzwalder,J. P. Pekola,D. M. Zumbuhl
DOI: https://doi.org/10.1063/1.4744944
2012-06-08
Abstract:We present an improved nuclear refrigerator reaching 0.3 mK, aimed at microkelvin nanoelectronic experiments, and use it to investigate metallic Coulomb blockade thermometers (CBTs) with various resistances R. The high-R devices cool to slightly lower T, consistent with better isolation from the noise environment, and exhibit electron-phonon cooling ~ T^5 and a residual heat-leak of 40 aW. In contrast, the low-R CBTs display cooling with a clearly weaker T-dependence, deviating from the electronphonon mechanism. The CBTs agree excellently with the refrigerator temperature above 20 mK and reach a minimum-T of 7.5 +/- 0.2 mK.
Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?