500 microkelvin nanoelectronics

Matthew Sarsby,Nikolai Yurttagül,Attila Geresdi
DOI: https://doi.org/10.1038/s41467-020-15201-3
2020-12-02
Abstract:Fragile quantum effects such as single electron charging in quantum dots or macroscopic coherent tunneling in superconducting junctions are the basis of modern quantum technologies. These phenomena can only be observed in devices where the characteristic spacing between energy levels exceeds the thermal energy, $k_\textrm{B}T$, demanding effective refrigeration techniques for nanoscale electronic devices. Commercially available dilution refrigerators have enabled typical electron temperatures in the $10$ to $100\,$mK regime, however indirect cooling of nanodevices becomes inefficient due to stray radiofrequency heating and weak thermal coupling of electrons to the device substrate. Here we report on passing the millikelvin barrier for a nanoelectronic device. Using a combination of on-chip and off-chip nuclear refrigeration, we reach an ultimate electron temperature of $T_\textrm{e}=421\pm35\,\mu$K and a hold time exceeding $85\,$hours below $700\,\mu$K measured by a self-calibrated Coulomb-blockade thermometer.
Mesoscale and Nanoscale Physics,Applied Physics,Instrumentation and Detectors
What problem does this paper attempt to address?
This paper aims to solve the problem of achieving ultra - low temperatures (on the order of micro - Kelvin) in nano - electronic devices. Specifically, the researchers attempt to reduce the electron temperature below 500 micro - Kelvin and maintain a long - term low - temperature state by combining on - chip and off - chip nuclear adiabatic demagnetization techniques. This technological breakthrough is crucial for observing fragile quantum effects such as the single - electron charging effect in quantum dots and the macroscopic coherent tunneling in superconducting junctions. These phenomena can only be observed when the energy - level spacing of the device exceeds the thermal energy \(k_BT\), so effective refrigeration techniques are required. ### Main problems and solutions 1. **Problem**: Traditional cooling methods such as dilution refrigerators can reduce the electron temperature to 10 - 100 milli - Kelvin, but in nano - scale devices, due to radio - frequency heating and weak thermal coupling between electrons and substrates, indirect cooling becomes inefficient. 2. **Solution**: The researchers adopted a nuclear adiabatic demagnetization technique combining on - chip and off - chip, using indium as a refrigerant, and successfully reduced the electron temperature to 421 ± 35 micro - Kelvin and maintained it for more than 85 hours. ### Experimental design - **Experimental device**: Use a commercial dilution refrigerator (MNK126 - 700, Leiden Cryogenics) and reduce the influence of electron noise on nanostructures through multiple microwave shielding layers. - **Magnetic field**: Apply a magnetic field of up to 13 Tesla through a superconducting solenoid. - **Refrigerant**: Use indium as a refrigerant, form cooling fins on the chip by electrodeposition, and connect them to a copper block through an epoxy resin film to provide additional thermal isolation. - **Temperature measurement**: Use a Coulomb - blockade thermometer (CBT) to directly measure the electron temperature. The CBT is based on the general suppression phenomenon of charge fluctuations in small metal islands at low electron temperatures, and the temperature is determined by measuring the zero - bias conductance. ### Key results - **Lowest electron temperature**: Through the nuclear adiabatic demagnetization technique, the electron temperature was successfully reduced to 421 ± 35 micro - Kelvin. - **Long - term maintenance**: In the temperature range below 700 micro - Kelvin, the maintenance time exceeds 85 hours. - **Heat leak calculation**: Through the temperature rise rate calculation, the heat leak of each island is estimated to be 26.7 atto - watts, which is lower than the previous result using copper refrigerant (32 atto - watts). - **Adiabatic efficiency**: Through the magnetic field cycling experiment, it was verified that the adiabatic efficiency of the system is close to 100%, indicating very precise control of the electron temperature. ### Significance This research not only realizes the stable refrigeration of nano - electronic devices at the micro - Kelvin level, but also provides the possibility for exploring strange electronic states such as topological order, electron - nuclear - spin ferromagnet, and p - wave superconductivity. In addition, this technique is expected to improve the performance of various quantum devices, such as the error rate of single - electron charge pumps and superconducting quantum circuits.