Radio-frequency Bloch-transistor electrometer

A. B. Zorin
DOI: https://doi.org/10.1103/PhysRevLett.86.3388
2000-12-17
Abstract:A quantum-limited electrometer based on charge modulation of the Josephson supercurrent in the Bloch transistor inserted into a superconducting ring is proposed. As this ring is inductive coupled to a high-Q resonance tank circuit, the variations of the charge on the transistor island (input signal) are converted into variations of amplitude and phase of radio-frequency oscillations in the tank. These variations are amplified and then detected. The output noise, the back-action fluctuations and their cross-correlation are computed. It is shown that our device enables measurements of the charge with a sensitivity which is determined by the energy resolution of its amplifier, that can be reduced down to the standard quantum limit of \hbar/2. On the basis of this setup a "back-action-evading" scheme of the charge measurements is proposed.
Superconductivity,Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a quantum - limit charge detector based on Bloch transistors to achieve high - sensitivity measurement of charge. Specifically, the paper proposes a new radio - frequency Bloch transistor charge detector (rf - Bloch - electrometer). This device inserts a Bloch transistor into a superconducting loop and inductively couples it with a high - frequency resonant circuit, thereby converting the charge change on the island into the change of the amplitude and phase of the oscillation in the resonant circuit. These changes are then amplified and detected. The key contributions of the paper are as follows: 1. **Improving charge detection sensitivity**: By controlling the alternating - supercurrent in the Bloch transistor, the sensitivity of charge detection can be effectively improved, reaching or approaching the standard quantum limit (SQL), that is, the energy resolution \(\epsilon \geq \frac{\hbar}{2}\). 2. **Reducing back - action noise**: The paper also explores how to design a "back - action - evading" measurement scheme so that the internal noise of a quadrant component can be compressed below the SQL, enabling accurate measurement without destroying the quantum state. 3. **Applicable to qubit measurement**: This new - type detector not only has high sensitivity, but also its sensor part (superconducting loop and transistor) is usually made of superconducting materials, which helps to reduce normal electron excitation, thereby prolonging the decoherence time of qubits, making it particularly suitable for qubit - state measurement in quantum computing. In conclusion, this paper aims to develop a high - performance charge detector to meet the high - precision measurement requirements in the field of quantum information processing.