Measurement of plasma parameters in an electron source with a plasma cathode based on a low-pressure arc discharge
S Yu Doroshkevich,M S Vorobyov,S S Kovalsky,I V Lopatin,N N Koval,S A Sulakshin
DOI: https://doi.org/10.1088/1742-6596/1393/1/012006
2019-11-01
Journal of Physics: Conference Series
Abstract:Abstract In the electron source with a grid plasma cathode based on a low-pressure arc discharge, the parameters of the emission plasma were investigated depending on the different conditions of its generation (type of gas, operating pressure, discharge current amplitude, resistance in the hollow anode circuit of a plasma emitter). For this purpose, a single cylindrical Langmuir probe was used. To measure the current-voltage characteristics of the probe, taking into account the features of the functioning of the electron source (galvanic isolation from high accelerating voltage, the use of high-voltage cables with high parasitic parameters, etc.), an automated measurement circuit was used, allowing for a relatively short time to collect high statistics of experimental data (depending on the frequency the impulses of the discharge current and their total number). To eliminate the influence of the parasitic parameters of the circuit, the measurement circuit was located in the maximum proximity to the generation space of the emission plasma (in a vacuum chamber), which significantly increased the accuracy of the experimental data obtained.