Design on a Two-tage Stirling / Pulse TubeS
Hybrid Cryocooler,C. H Yin,Z. H Gan,B. Wang,Y. X. Guo
2016-01-01
Abstract:In the field of military and aerospace, there are strict requirements for cryocoolers, such as high efficiency, compactness, light weight, high reliability, long life and low vibration limits. At present, most mechanical cryocoolers which can be applied in space are Stirling cryocoolers and Stirling type pulse tube cryocoolers. Two-stage cryocoolers are sought-after for aerospace applications, since the performance of single-stage cryocoolers is limited below 35 K, especially at 20 K. Compared with two-stage Stirling cryocoolers, Stirling/pulse tube hybrid cryocoolers eliminate the moving parts of the second stage, which leads to longer life. Moreover, hybrid cryocoolers can achieve higher pressure ratios and efficiency in their regenerator due to a better match in charging pressure between stages. In this study, we designed a two-stage Stirling/pulse tube hybrid cryocooler at 20 K with low temperature inertance tubes and a surge volume to adjust the phase difference. We simulated the performance of the designed cryocooler using the Sage code, and proved that the as-designed cryocooler can provide 0.54 W cooling power at 20 K with 180 W electrical power input. In addition, the effects of the phase difference, mass flow, and pressure ratio in the displacer are also discussed.