Asymmetric Data Acquisition System for an Endoscopic PET-US Detector

Carlos Zorraquino,Ricardo Bugalho,Manuel Rolo,Jose C. Silva,Viesturs Vecklans,Rui Silva,Catarina Ortigao,Jorge A. Neves,Stefaan Tavernier,Pedro Guerra,Joao Varela
DOI: https://doi.org/10.1109/TNS.2016.2514600
2015-11-03
Abstract:According to current prognosis studies of pancreatic cancer, survival rate nowadays is still as low as 6% mainly due to late detections. Taking into account the location of the disease within the body and making use of the level of miniaturization in radiation detectors that can be achieved at the present time, EndoTOFPET-US collaboration aims at the development of a multimodal imaging technique for endoscopic pancreas exams that combines the benefits of high resolution metabolic information from Time-Of- Flight (TOF) Positron Emission Tomography (PET) and anatomical information from ultrasound (US). A system with such capabilities calls for an application-specific high-performance Data Acquisition System (DAQ) able to control and readout data from two different detectors.
Medical Physics,Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to increase the early detection rate of pancreatic cancer, thereby improving the survival rate of patients. According to current prognostic studies, the 5 - year survival rate of pancreatic cancer is still as low as 6%, mainly due to late discovery. To improve this situation, the EndoTOFPET - US collaborative project aims to develop a multi - modal imaging technique for endoscopic pancreatic examination, combining high - resolution metabolic information (from Time - Of - Flight Positron Emission Tomography, TOF - PET) and anatomical information (from Ultrasound, US) to achieve earlier and more accurate lesion detection. Specifically, the system includes two novel detectors: 1. **PET head extension**: Placed inside a commercial US endoscope, close to the Region - Of - Interest (ROI). 2. **PET plate**: Placed on the patient's abdomen, working in synergy with the PET head. These two detectors will generate asymmetric data streams, so a high - performance application - specific Data Acquisition System (DAQ) is required, which can control and read data from different detectors. The DAQ system is designed as a distributed multi - level trigger architecture, distributed in the two - detector electronics and off - detector electronics in the image reconstruction workstation. Through this innovative DAQ system design, the research team hopes to achieve the following goals: - Increase the image spatial resolution to 1 millimeter. - Achieve an unprecedented 200 picoseconds (ps) Coincidence Time Resolution (CTR) to enhance background rejection. - Track the two detectors online and use the partial volume information of the asymmetric geometry for image reconstruction. In conclusion, the core issue of this paper is how to improve the early detection ability and image quality of pancreatic cancer by developing advanced multi - modal imaging techniques and corresponding data acquisition systems, and ultimately improve the survival rate of patients.