PEBS - Positron Electron Balloon Spectrometer

P. von Doetinchem,H. Gast,T. Kirn,G. Roper Yearwood,S. Schael
DOI: https://doi.org/10.1016/j.nima.2007.07.053
2007-02-21
Abstract:The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was needed to design a detector which could increase the existing data by more than a factor of 100. Using silicon photomultipliers for the readout of a scintillating fiber tracker and of an imaging electromagnetic calorimeter, the PEBS detector features a large geometrical acceptance of 2500 cm^2 sr for positrons, a total weight of 1500 kg and a power consumption of 600 W. The experiment is intended to measure cosmic ray particle spectra for a period of up to 20 days at an altitude of 40 km circulating the North or South Pole. A full Geant 4 simulation of the detector concept has been developed and key elements have been verified in a testbeam in October 2006 at CERN.
Astrophysics
What problem does this paper attempt to address?
The main objective of this paper is to design a novel balloon-borne cosmic ray spectrometer (PEBS) to improve the measurement accuracy of cosmic ray positron flux. Specifically, the paper aims to address the following key issues: 1. **Increase Data Volume**: The best existing measurement data was obtained by the HEAT balloon experiment over 10 years ago, but due to weight and power consumption limitations, the data volume from these experiments is limited. Therefore, a new detector design is needed to significantly increase the data volume and improve measurement accuracy. 2. **Indirect Detection of Dark Matter**: By precisely measuring the positron component in cosmic rays, important clues can be provided for the study of dark matter. Certain theoretical models (such as the supersymmetry model) predict a new particle called the neutralino, which may be one of the dark matter candidates. Dark matter annihilation produces positrons, so measuring the positron flux can help indirectly detect the presence of dark matter. 3. **Background Suppression**: The proton background in cosmic rays occupies the major part. To accurately measure the positron signal, it is necessary to achieve high-precision proton background suppression capability (up to the order of 10^6). 4. **Momentum Resolution Capability**: To determine the charge sign and further suppress the electron signal, good momentum resolution capability is required. In summary, this paper aims to achieve precise measurement of the positron component in cosmic rays through the design and simulation of the PEBS detector, thereby providing strong support for the indirect detection of dark matter.