Misalignment-Tolerant Planar Spiral Coil Pair Design for 13.56 MHz Inductive Coupling of Wireless Resistive Analog Passive Sensors

Babak Noroozi,Bashir I. Morshed
DOI: https://doi.org/10.3390/s24030752
IF: 3.9
2024-01-24
Sensors
Abstract:Long-term daily-life body signal monitoring offers numerous advantages, such as timely response to health alerts, diseases monitoring, and reducing time and expenses related to clinical trials. Access to physiological data can be achieved with low-cost and comfortable wireless wearable sensors. In our previous publication, we reported a low-cost, easy to implement, and unobtrusive wireless resistive analog passive (WRAP) sensor to provide a feasible bio-signal monitoring technique by using a pair of printed spiral coils (PSC) in a near field connection. Sensitivity, defined as the response to the transducer, is a critical feature in the establishment of a reliable system. In the previous publication, we presented the utilization of a Genetic Algorithm to design a pair of coils and related components to maximize sensitivity. Although the coils' misalignment can significantly affect the optimized sensitivity, it was not incorporated into the optimization process. This paper focuses on optimizing the coils and components in order to maximize both their sensitivity and their resilience against movements of the PSC pair. In a square-shaped pair comprising a primary coil of 60 mm and a secondary coil of 20 mm dimensions, we found that the sensitivity is maximized at 1.3 mƱ for a 16 mm axial distance. Additionally, it remains above 0.65 mƱ within ±11.25 mm lateral and +14 mm axial displacements.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the sensitivity of the wireless resistive analog passive (WRAP) sensor in 13.56 MHz inductive coupling, while reducing the sensitivity degradation caused by the misalignment of planar spiral coil pairs (PSC). Specifically, the paper focuses on the following points: 1. **Sensitivity Optimization**: Maximize the sensitivity of the system by optimizing the coil design and its related components. Sensitivity refers to the ability of the system to respond to changes in sensor resistance, which is crucial for reliable biosignal monitoring. 2. **Anti - misalignment Ability**: In practical applications, the relative position of the coils may change (i.e., misalignment), which will significantly affect the optimized sensitivity. Therefore, the paper proposes a method to optimize the coil design so that it can still maintain high sensitivity when misalignment occurs. 3. **Consideration of Coupling Factor**: The coupling factor \(k\) is an important parameter for measuring the magnetic flux transfer efficiency between two coils. The paper takes the coupling factor as a variable in the optimization process to more accurately reflect the situation in actual use. ### Specific Problems and Solutions - **Problem Background**: - Long - term daily body signal monitoring can respond to health alarms and disease monitoring in a timely manner, and reduce the time and cost of clinical trials. - Low - cost and comfortable wireless wearable sensors can obtain physiological data. - Although the coil pairs designed in previous studies have high sensitivity, the influence of coil misalignment has not been considered. - **Solutions**: - **Optimization Method**: Use the genetic algorithm (GA) to optimize the coil design and its related components to maximize sensitivity and reduce sensitivity to misalignment. - **Introduction of Coupling Factor**: Take the coupling factor \(k\) as an optimization variable to ensure that the optimization results are more stable in practical applications. - **Boundary and Constraint Conditions**: Define the upper and lower limits of each variable and add two constraint conditions to ensure the feasibility of the coil structure. - **Simulation Verification**: Determine the relationship between the coupling factor and the coil position through finite element analysis (FEA) simulation, and verify the accuracy of the optimization results. ### Main Contributions - **Theoretical Model**: Establish a detailed circuit model and equations to describe the relationship between sensitivity and various parameters. - **Optimization Algorithm**: Propose an improved genetic algorithm, combine the optimization of components and coil specifications into one step, and introduce the coupling factor as a variable. - **Experimental Verification**: Verify the effectiveness of the optimization results through FEA simulation, and show the performance of the optimized coil at different positions. In general, this paper aims to improve the performance of wireless resistive analog passive sensors in practical applications by optimizing the coil design and its related components, especially when the coils may be misaligned.