Noether Symmetries and Critical Exponents

Yuri Bozhkov
DOI: https://doi.org/10.3842/SIGMA.2005.022
2005-11-27
Abstract:We show that all Lie point symmetries of various classes of nonlinear differential equations involving critical nonlinearities are variational/divergence symmetries.
Exactly Solvable and Integrable Systems,Mathematical Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to measure the flatness of the LSST (Large Synoptic Survey Telescope) Focal Plane Assembly (FPA) in situ (i.e., in a low - temperature and vacuum environment). Specifically, the problems include: 1. **Measuring the flatness of the FPA**: When the FPA is installed on the telescope and ready to operate, how to ensure that its flatness meets the requirements (10 - micron peak - to - valley tolerance). Since the FPA is located inside a cryostat in a low - temperature and vacuum environment (- 100°C), conventional measurement methods are difficult to apply. 2. **Measuring the distance between the FPA and the L3 lens**: The FPA is only 25 millimeters away from the L3 lens, so a method is needed to accurately measure the distance between them. 3. **Detecting deformations caused by gravity and air pressure**: When the telescope moves at different azimuths, gravity and external air pressure may cause deformations of the L3 lens, so methods are needed to detect these changes. To solve these problems, the author proposes a simple and cost - effective laser - based method that can measure the flatness of the FPA in a low - temperature and vacuum environment and may detect deformations of the L3 lens. This method projects a large number of light spots on the FPA and infers changes in the flatness of the FPA by analyzing the position, shape, and orientation of these light spots. ### Key Point Summary - **Measurement Environment**: The FPA is located in a low - temperature and vacuum environment with a temperature of - 100°C. - **Measurement Objectives**: Ensure that the flatness of the FPA is within 10 microns and measure the distance between the FPA and the L3 lens. - **Innovation Points**: Use laser - projected light spots and combine the analysis of the position, shape, and orientation of the light spots to achieve high - precision measurement. - **Potential Applications**: It can not only measure the flatness of the FPA but also detect deformations of the L3 lens. The advantages of this method are low cost, easy implementation, and the ability to directly use FPA sensors for measurement without the need for complex modifications to the existing structure.