The Tube Furnace with Online Mass Loss Measurement as a New Bench Scale Test for Pyrolysis

Karen De Lannoye,Alexander Belt,Ernst-Arndt Reinecke,Lukas Arnold
DOI: https://doi.org/10.1007/s10694-024-01590-0
IF: 3.605
2024-06-20
Fire Technology
Abstract:In this paper, a new gram scale experiment with well characterised boundary conditions is proposed for pyrolysis experiments. The set-up consists of a tube furnace, based on ISO19700, with a newly designed concept for a balance within the oven, allowing for online mass loss measurements. Samples with a length up to 50 cm can be investigated in this apparatus. The oven allows for experiments at fixed temperatures or at fixed heating rates, under controlled atmosphere, w.r.t. gas composition and flow rate. A thorough characterisation of the set-up is presented, including aspects like reproducibility of the heating rate or the precision of the balance. The functionality of the balance has been demonstrated with calcium carbonate (CaCO ) experiments. This material was chosen because it decomposes in a single reaction, which only releases CO . This allows for comparison between the mass loss rate of the balance and the CO production rate, measured by a gas analyser. Results for two different heating rates: 3 K/min and 5 K/min and for different masses (25 g and 8.5 g) are presented. The two measurement methods are in excellent agreement. Finally, the data obtained from the new experimental set-up is compared to results from thermogravimetric analyser (TGA) experiments.
materials science, multidisciplinary,engineering
What problem does this paper attempt to address?
The paper attempts to address the gap between experiments and modeling in cable fire research. Specifically: 1. **Limitations of existing experimental methods**: - The cone calorimeter, although commonly used, cannot well control conditions such as flow rate or convective cooling around the sample due to its layout. These factors make the boundary conditions more complex, especially when testing cables. - The thermogravimetric analyzer (TGA), while having good boundary condition control, is only suitable for very small samples (milligram level), making it difficult to obtain representative cable samples. 2. **Design of a new experimental apparatus**: - The paper proposes a new tube furnace experimental apparatus that combines the advantages of the cone calorimeter and TGA, capable of handling larger, more representative samples and conducting experiments under controlled conditions. - The new apparatus is designed based on the ISO 19700 standard. Its novelty lies in the ability to install a balance inside the furnace, enabling online mass loss measurement, thus obtaining real-time mass loss data under controlled atmosphere, temperature, and flow conditions. Through this new apparatus, researchers aim to bridge the gap between existing experimental methods and modeling to better understand the dynamics of cable fires.