Finite element modeling and validation of the normal cervical spine using MIMICS and Abaqus

N. Lin
Abstract:[Objective]This study was conducted to develop a detail,three dimensional and anatomically accurate finite element model(FEM) of human cervical spine structure and validate it against other FEM and in vitro experimental data,for the use of subsequent biomechanical analyses of human cervical.[Methods]The computed tomography data of a disease-free male volunteer were used in the study.The pictures were input to MIMICS software to process and output a three-dimension entity model,then the model was inputted into the FE software Abaqus to divide into mesh,added discs and main ligaments and muscles,and then a cervical FEM was obtained.The model accuracy was validated by comparing it with previously published FE model and in vitro experimental results for different movements of anteflexion,lateral bending and axial rotation.[Results]The complete FEA model comprised six vertebras of C2~7,five discs of C2、3~C6、7,posterior structure and the main ligaments of the cervical spine,which consisted of 472065 elements and 98708 node points.The results show that force-displacement response under anteflexion,lateral bending and axial rotation was correlated well with previous literature and experimental results.[Conclusion]The established FEM is accurate with the human cervical spine and is competent in the use of the biomechanical analysis in clinical study of cervical spine.
Medicine,Engineering