Abstract:Objective To develop a valid mathematic model for the research of the neutral zone(NZ) in craniovertebral junction.Method An anatomic detailed,nonlinear finite element(FE) model of the occipito-atlanto-axial(C0-C1-C2) complex based on Visible Human Male dataset was developed in this study,which can improve the previous upper cervical spine FE models by its increased geometric modeling accuracy and more precise material assignment.The model simulated the movements of upper cervical spine under axial rotation,flexion,extension,and lateral bending under physiological static loadings.Result The range of motion(ROM) and NZ agreed well with published experimental data.The moment-rotation relationship predicted by this model was apparently nonlinear,and the largest rotation was predicted in horizontal plane,followed by median plane and coronal plane. Axial rotations and lateral bending were strongly coupled with each other.The complex exhibited large ROM and high proportions of NZ to ROM.Conclusion There are no published results of FE models of upper cervical spine by far that have already undergone validations for both ROM and NZ.Therefore,it can be concluded that the current FE model validated for NZ is useful in the investigation of abnormal NZ in disease and trauma of craniovertebral junction.
What problem does this paper attempt to address?