Microstructure and stress corrosion cracking behavior of Alloy 690TT steam generator tubes with internal bulge defect

Bin Wu,Hongliang Ming,Zhiming Zhang,Fanjiang Meng,Guangqing He,Jianqiu Wang,En-Hou Han
DOI: https://doi.org/10.1016/j.jnucmat.2022.153629
IF: 3.555
2022-05-01
Journal of Nuclear Materials
Abstract:Alloy 690TT tube samples with different sizes of internal bulge defect (IBD) are prepared by actual hydraulic tube expansion in field and their microstructure and stress corrosion cracking (SCC) behavior are studied in detail. The hardening level and residual strain increase as moving from the original area of the tube to the bulged area, and so as for the increasing of deformation sizes. Corrosion test with a duration of 2000 h shows that the IBD area has higher SCC sensitivity than the original tube. In addition, IBD with larger size is more sensitive to SCC.
materials science, multidisciplinary,nuclear science & technology