Pervaporation separation of toluene/n-heptane mixtures using a MSE-modified membrane: Effects of operating conditions

Mona Iravaninia,Mojtaba Mirfendereski,Toraj Mohammadi
DOI: https://doi.org/10.1016/j.cherd.2011.07.020
IF: 4.119
2012-03-01
Chemical Engineering Research and Design
Abstract:In this work, separation of toluene/n-heptane mixtures via pervaporation using a composite membrane was investigated. Effects of operating conditions such as feed temperature, feed composition and downstream pressure on the membrane performance were studied. Experimental results were obtained at different feed compositions (10–40wt.%), operating temperatures (25–85°C) and downstream pressures (2–32mbarg). The membrane selectivity for toluene was found to be greater than that for n-heptane. According to the results, it was observed that increasing toluene concentration in the feed and operating temperature enhance the membrane swelling and increase the polymeric chain mobility. Therefore, feed concentration and temperature have the same effects on toluene selectivity and permeation flux of the membrane. Permeation flux increases and toluene selectivity decreases with increasing feed concentration and temperature. In contrary, the membrane performance enhances with decreasing downstream pressure. It was found out that for a feed with 10wt.% of toluene, at a temperature of 85°C and a downstream pressure of 2mbarg, the highest PSI value of 18.371kg/m2 h (in which permeation flux=4.610kg/m2 h and toluene selectivity=4.985) is achieved.
What problem does this paper attempt to address?