Experimental investigation of eutectic PCM incorporated clay brick for thermal management of building envelope

Samad Ali Taj,Waqas Khalid,Hassan Nazir,Aamir Khan,Muhammad Sajid,Adeel Waqas,Arsalan Hussain,Majid Ali,Ahmad Zaki,Sheikh Ahmad Zaki
DOI: https://doi.org/10.1016/j.est.2024.110838
IF: 9.4
2024-04-01
Journal of Energy Storage
Abstract:Global warming is mainly triggered by the consumption of fossil fuels and the phenomenon has shaken the global community in the form of climate change resulting in frequent heat waves leading to drought and catastrophic wildfires. At present increase in global average temperature is further increasing energy demands for maintaining thermal comfort inside the building envelope. In such circumstances building materials with improved thermal performance can reduce thermal load inside the building envelope. The study aimed to improve the thermal performance of clay brick, which is a key building material, by incorporating organic eutectic phase change materials as latent heat thermal energy storage medium. Considering the average hot summer temperature 34–37 °C in Islamabad, Pakistan, Lauric acid and Palmitic acid were selected for preparation of eutectic mixtures possessing a melting temperature range of 33–38 °C. Differential Scanning Calorimetry was performed to determine thermophysical properties of pristine material and prepared eutectic mixtures such as melting-solidification characteristics and latent heat. Thermogravimetric analysis was also performed to determine the thermal stability of the studied phase change materials. Two separate test compartments were designed and developed to analyse the reduction in temperature and respective thermal load. One test compartment comprised of PCM-incorporated clay bricks, while the other with clay brick were made and investigated under direct sunlight and in controlled conditions, respectively. Considering the charging and discharging of PCM, both heating and cooling temperature profiles of individual bricks and compartments were examined by incorporating multiple k-type thermocouples. Structural strength and compressive strength analysis of modified brick was also conducted. A decrease of 4–5.5 °C in the inside temperature of the compartment, ∼32 % reduction in thermal amplitude inside PCM compartment, decrement factor of 0.91 for PCM incorporated brick and a maximum time lag of 150 min was observed. The overall reduction in heat flux inside PCM incorporated bricks compartment was ∼25–30 %.
energy & fuels
What problem does this paper attempt to address?