Flow field analysis and design optimisation of Tibetan medicine double heat pump drying room
Mingyuan Shi,Ying Zhang,Yunfeng Wang,Meng Gao,Jin Li,Zhihan Deng,Rui Liu,Ming Li
DOI: https://doi.org/10.1016/j.compag.2022.107141
IF: 8.3
2022-08-01
Computers and Electronics in Agriculture
Abstract:The drying performance of a heat pump drying room primarily depends on the uniformity of the air distribution. The air distribution is affected by parameters such as circulating fan and condenser resistance. This study aims to improve the uniformity of the air distribution in a heat pump drying room. In this study, a three-dimensional simulation of the air distribution in a drying room was carried out using computational fluid dynamics software. A porous medium model and multiple reference frame model were adopted in this study. The results obtained from the models were in agreement with the experimental results, with a discrepancy of 7%. The simulation results showed that the airflow uniformity was poor at the fan outlet and opening of the clapboard. Moreover, a large amount of air flowed through the uppermost zone of the drying room. Subsequently, a type of wind deflector structure was designed to improve the uniformity of the airflow at the fan outlet, and the optimal separation size of the wind board was determined using numerical calculations. The standard deviation of the outlet airflow rate of the final diversion cover was 0.001. The optimised uniformity index of the wind speed in the drying room was 0.81, which was 8% higher than that of the original structure.
agriculture, multidisciplinary,computer science, interdisciplinary applications