Thermal performance optimization of novel vertical latent heat storage unit with frustum wavy tube

Lihua Ding,Yuan Fang,Chenyu Zhang,Hongtao Xu
DOI: https://doi.org/10.1016/j.icheatmasstransfer.2024.108240
IF: 6.782
2024-10-24
International Communications in Heat and Mass Transfer
Abstract:Low thermal conductivity of phase change materials (PCMs) hinders heat transfer in latent heat systems. Geometry optimization of latent heat storage units (LHSUs) could help to enhance heat transfer performance. This study proposes a vertical LHSU with frustum wavy tube, aiming to find its optimal parameters. Six LHSU designs were simulated using enthalpy-porosity method, comparing their performances under the conditions of 0.13 kg/s for mass flow rate, 70 °C and 10 °C for the inlet temperature for charging and discharging process, respectively. The frustum wavy tube LHSU (FW-LHSU) showed the best overall performance. For the ranges of wall tilt angle ( θ ) from 2° to 8°, wave number ( N ) from 6 to 12 and wave amplitude( A ) from 3 mm to 6 mm, Taguchi method determined the optimal parameters as 8° for θ , 6 for N and 6 mm for A . Variance analysis ranked their importance as A > N > θ , contributing 83.65 %, 10.18 %, and 3.96 %, respectively, in performance improvement. Inlet temperature variation slightly affected FW-LHSU charging process. Under steady conditions, a 60–80 °C increase in inlet boosted specific charging rate by 81.45 %.
thermodynamics,mechanics
What problem does this paper attempt to address?