A Low-Power High-Sensitivity Photocurrent Sensory Circuit with Capacitive Feedback Transimpedance for Photoplethysmography Sensing

Neethu Mohan,Falah Awwad,Nabil Albastaki,Mohamed Atef
DOI: https://doi.org/10.3390/s24134097
IF: 3.9
2024-06-24
Sensors
Abstract:This study presents an integrated analog front-end (AFE) tailored for photoplethysmography (PPG) sensing. The AFE module introduces a novel transimpedance amplifier (TIA) that incorporates capacitive feedback techniques alongside common drain feedback (CDF) TIA. The unique TIA topology achieves both high gain and high sensitivity while maintaining low power consumption. The resultant PPG sensor module demonstrates impressive specifications, including an input noise current of 4.81 pA/sqrt Hz, a transimpedance gain of 18.43 MΩ, and a power consumption of 68 μW. Furthermore, the sensory system integrates an LED driver featuring automatic light control (ALC), which dynamically adjusts the LED power based on the strength of the received signal. Employing 0.35 μm CMOS technology, the AFE implementation occupies a compact footprint of 1.98 mm × 2.475 mm.
engineering, electrical & electronic,instruments & instrumentation,chemistry, analytical