Polymerization shrinkage stress of contemporary dental composites: Comparison of two measurement methods

Agata Szczesio-Wlodarczyk,Sufyan Garoushi,Pekka Vallittu,Kinga Bociong,Lippo Lassila,Agata SZCZESIO-WLODARCZYK,Sufyan GAROUSHI,Pekka VALLITTU,Kinga BOCIONG,Lippo LASSILA
DOI: https://doi.org/10.4012/dmj.2023-192
2024-01-01
Dental Materials Journal
Abstract:The aim of this study was to compare two testing methodologies employed for assessing the polymerization shrinkage stress of dental resin composites. Ten commercial resin composites were investigated (EverX Posterior & Flow; G-ænial Anterior, Posterior, A'CHORD & Universal Injectable; Filtek One Bulk Fill & Universal Restorative; SDR flow+ and Aura Bulk Fill). Photoelastic and contraction forces measurement methods were performed. The slope of the linear trendline and C-factor of specimens were calculated. The shrinkage stress values (range between: 6.4-13.4 MPa) obtained by the photoelastic method were higher for all resin composites than the values obtained by contraction forces measurements (range between 1.2-4.8 MPa). However, there was a strong linear correlation between these methods (r=0.8). The use of both investigated methods revealed important information about the shrinkage behavior of the restorative resin composites.
materials science, biomaterials,dentistry, oral surgery & medicine
What problem does this paper attempt to address?