Study on the Cooling Performance of a Focused Ultrasonic Radiator for Electrical Heating Elements

Songfei Su,Yang Wang,Lukai Zheng,Mengxin Sun,Qiang Tang,Huiyu Huang
DOI: https://doi.org/10.3390/mi15010116
IF: 3.4
2024-01-11
Micromachines
Abstract:In this work, a focused ultrasonic radiator is proposed for cooling the electrical heating elements in the focal region, and its working characteristics are investigated. The analyses of the FEM computational and flow field visualization test results indicate that focused ultrasound can generate forced convective heat transfer by the acoustic streaming in the focal region, which can cool the heating elements effectively. Experiments show that when the input voltage is 30Vp-p and the ambient temperature is 25 °C, the focused ultrasonic radiator can cause the surface temperature of the heating element (high-temperature alumina ceramic heating plate with a diameter of 5 mm) in the focal region to drop from 100 °C to about 55 °C. When the diameter of the electrical heating element is changed from 5 mm to 30 mm, the cooling effect is similar in the focal region. Compared with a fan, the focused ultrasound radiator has a shorter cooling time and a more concentrated cooling area. The focused ultrasonic radiator proposed in this work is suitable for some special environments.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The paper aims to study the performance of a novel focused ultrasound radiator in cooling electric heating elements. Specifically, the paper proposes a focused ultrasound radiator and conducts a detailed study of its operating characteristics. Through finite element method (FEM) calculations, flow field visualization tests, and experimental result analysis, it is shown that focused ultrasound can generate forced convective heat transfer in the focal area, thereby effectively cooling the heating elements. Experimental results show that under an input voltage of 30Vp-p and an ambient temperature of 25°C, the focused ultrasound radiator can reduce the surface temperature of a high-temperature alumina ceramic heating plate (diameter 5 mm) located in the focal area from 100°C to approximately 55°C. Additionally, when the diameter of the electric heating element changes from 5 mm to 30 mm, the cooling effect in the focal area remains similar. Compared to a fan, the focused ultrasound radiator has a shorter cooling time and a more concentrated cooling area. Therefore, this focused ultrasound radiator is suitable for cooling needs in certain special environments.