Abstract:The polymer electrolyte membrane fuel cells are proven to be clean renewable energy conversion systems; however, the cylindrical structures have numerous potentials in low-power applications owing to their higher gravimetric and volumetric power densities. In this study, a three-dimensional axisymmetric computational fluid dynamics model is developed for a cylindrical structure and is further validated for cell performance at different clamping pressures (0.5–2.5 MPa). The optimum contact resistance for the cell is observed to be 0.40 Ω-cm 2 for a clamping pressure of 1.5 MPa at the interface of the cathode gas diffusion layer and cathode current collector. In addition, a structural model is developed with the variation in thickness of the cathode current collector (0.25–1.5 mm) and gas pressure (0.5–3.0 bar) for different clamping systems. The results indicate an enhancement in the cell performance (58.58 W/m 2 to 138.96 W/m 2 at 0.6 V) with optimum clamping (1.5 MPa) and gas pressure (1 bar) due to better contact pressure distribution at the interface. The thickness of the cathode current collector is also optimized to 1.0 mm for a new (spring) clamping system owing to ∼1.6 times better contact and 66% less resistance to that of conventional (strap) clamping mechanism.
energy & fuels,electrochemistry,chemistry, physical
What problem does this paper attempt to address?