A Fast and Robust Open-Switch Fault Diagnosis Method for Variable-Speed PMSM System

Xinxiu Zhou,Jun Sun,Peiling Cui,Yanhua Lu,Ming Lu,Yang Yu
DOI: https://doi.org/10.1109/tpel.2020.3013628
IF: 5.967
2021-03-01
IEEE Transactions on Power Electronics
Abstract:Traditional open-switch fault diagnosis methods suffer from poor rapidity or robustness. To solve this issue, a new differential current observer-based fault diagnosis method is proposed in this article. With the designed differential observer, fault symptoms (residuals) can be generated and adopted for fault diagnosis easily. Considering that the residuals are sensitive to motor operating condition in the conventional model-based method due to model error, an adaptive fault detection threshold is designed. As a result, the false detection and missed detection caused by the change of working condition can be avoided, and stronger robustness against speed, load, and parameter variations can be achieved with superior rapidity compared with existing methods. Finally, the rapidity and robustness of the proposed fault diagnosis method are verified sufficiently through experimental results.
engineering, electrical & electronic
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to diagnose open - circuit switch faults quickly and reliably in the permanent magnet synchronous motor (PMSM) system. Traditional open - circuit switch fault diagnosis methods have problems such as slow response speed or poor robustness, especially under variable - frequency conditions. These methods are difficult to ensure both rapid detection and high robustness simultaneously. This paper proposes a fault diagnosis method based on a differential current observer and designs an adaptive fault detection threshold to improve the speed of fault diagnosis and the robustness to speed changes, load changes and parameter errors. Specifically, by analyzing the terminal voltage distortion characteristics caused by open - circuit switch faults, the paper designs a differential current observer to generate fault symptoms (residuals). In order to reduce false detections and missed detections caused by changes in working conditions, an adaptive fault detection threshold is also designed. This method can not only detect faults quickly, but also maintain high robustness under different working conditions. The effectiveness of this method has been verified through experiments.