A MEMS Rate-Integrating Gyroscope (RIG) With In-Run Automatic Mode-Matching

Qi Fan,Yi Zhou,Mengxiang Liu,Chen Lin,Yan Su
DOI: https://doi.org/10.1109/jsen.2021.3137245
IF: 4.3
2022-02-01
IEEE Sensors Journal
Abstract:Toward the objective of eliminating the angle error and rate threshold of the rate integrating gyroscope (RIG) caused by stiffness asymmetry, a novel in-run automatic mode-matching method is presented in this paper. Although other manual mode-matching methods can reduce the stiffness asymmetry temporarily, the environmental factors will interfere the manual calibration. Combined with virtual rotation, the processing circuits obtain the resonant frequencies of RIG operation modes and a controller is used to reduce the frequency difference. Meanwhile, an innovative method is proposed for RIG angle error analysis, avoiding the drawbacks of the traditional analysis methods. An FPGA based platform using a MEMS disk resonator is tested and the angle error is reduced to 1 degree compared with the manual calibration result 6.1 degrees.
engineering, electrical & electronic,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to eliminate the angular error and rate threshold problem of the Rate - Integrating Gyroscope (RIG) caused by stiffness asymmetry. Although the traditional manual pattern - matching method can temporarily reduce the stiffness asymmetry, environmental factors such as temperature changes will interfere with the calibration results, leading to performance degradation. Therefore, this paper proposes a novel automatic in - operation pattern - matching method. Combined with the virtual rotation technology, the resonant frequency of the RIG operation mode is obtained through the control system, and the controller is used to reduce the frequency difference, thus effectively solving the above - mentioned problems. ### Specific Problem Description 1. **Angular Error and Rate Threshold Problem**: - Stiffness asymmetry and damping asymmetry are the main error sources that lead to the RIG angular error and the minimum rate threshold. - Stiffness asymmetry will cause the frequency difference between operation modes, which in turn reduces the Coriolis coupling sensitivity and the angular gain. - Damping asymmetry will cause velocity coupling, making the vibration mode fixed on the minimum damping axis. Only when the rotation rate exceeds the threshold can the vibration mode precess freely. 2. **Limitations of Traditional Calibration Methods**: - The manual calibration method can only temporarily reduce the angular error caused by the frequency difference, but environmental factors (such as temperature changes) will affect the calibration results, leading to performance degradation. - Traditional analysis methods cannot accurately evaluate the influence of the frequency difference on the angular output, especially when the frequency mismatch exceeds the mechanical bandwidth of the resonator. ### Solutions To solve these problems, this paper proposes the following methods: 1. **Automatic In - operation Pattern - Matching Method**: - Combined with the virtual rotation technology, the resonant frequency of the RIG operation mode is obtained through the control system. - Use the controller to automatically adjust the tuning voltage to reduce the frequency difference, thus realizing the automatic pattern - matching during operation. - This method can dynamically adjust the frequency difference during the entire operation period and avoid the influence of environmental factors. 2. **Innovative Angular Error Analysis Method**: - A new analysis method is proposed, which divides the influence of the frequency difference into the gain path and the phase path, so as to obtain the explicit solution of the angular error. - This method avoids the defects of the traditional averaging method and is especially suitable for the case where the frequency mismatch exceeds the mechanical bandwidth of the resonator. 3. **Experimental Verification**: - The effectiveness of the proposed automatic pattern - matching method is verified by experiments. The results show that the angular error is reduced from 4.2 degrees to 1 degree, and the second - harmonic error is reduced from 4 degrees to 0.7 degree. ### Summary By proposing an automatic in - operation pattern - matching method, combined with the virtual rotation technology and the innovative angular error analysis method, this paper successfully solves the RIG angular error and rate threshold problems caused by stiffness asymmetry, and significantly improves the performance and stability of the RIG.