Optimal Tuning of the Current Loop for Dual-Loop Controlled Grid-Forming Converters Based on Active Damping Optimization

Zhihong Zhao,Zhipeng Han,Xunduan Liu,Jia Yao,Baojian Ji,Shuzheng Wang,Jianfeng Zhao
DOI: https://doi.org/10.1109/access.2021.3061098
IF: 3.9
2021-01-01
IEEE Access
Abstract:Effective sinusoidal voltage regulation is of permanent importance for grid-forming converters. Usually, the following two types of schemes are employed to achieve a high level of performance: 1) single-loop voltage and 2) dual-loop voltage-current control. The performance of both schemes has comprehensively been evaluated in this work, based on the developed discrete-time model of the LC-filtered grid-forming converter. The challenges of insufficient stability margin, constraint bandwidth, and high sensitivity to parameter variation faced by the single-loop control scheme have been addressed, if the high-performance resonant controllers are employed for voltage regulation. Alternatively, the dual-loop control does not experience such issues with the inclusion of inner-current loop which provides active damping for the overall system. The essence of the inner-current loop is identified based on the discrete root locus analysis. Also, to obtain the highest damping and most enhanced stability, the criterion for current loop design has been addressed and a method for optimal tuning of the inner-current loop is developed, where the original plant with the one-sampling delay and the current gain are considered as the equivalent plant for the voltage controller. Experimental results have verified the effectiveness of the developed method for regulation of grid-forming converters.
computer science, information systems,telecommunications,engineering, electrical & electronic
What problem does this paper attempt to address?
The paper aims to address the issue of effective sinusoidal voltage regulation in Grid-Forming Converters (GFCs). Specifically, the paper explores two commonly used control schemes: single-loop voltage control and dual-loop voltage-current control, and provides a comprehensive evaluation of these two schemes. 1. **Single-Loop Voltage Control**: This scheme uses only capacitor voltage feedback for regulation. However, this method has shortcomings in terms of high-frequency switching ripple and resonance stability issues caused by the LC filter. When high-performance resonant controllers are used, the single-loop control scheme has insufficient stability margin, limited bandwidth, and is very sensitive to parameter variations. 2. **Dual-Loop Voltage-Current Control**: This scheme includes an inner current loop that can provide active damping, thereby improving the overall system stability. The paper points out that dual-loop control can overcome the issues present in single-loop control and determines the nature of the inner current loop through discrete root locus analysis. Additionally, the paper proposes a method to optimize the inner current loop to achieve maximum damping and enhanced stability. In summary, the main objective of the paper is to address the stability issues faced by GFCs in practical applications by optimizing the design of the inner current loop in dual-loop control and to validate the effectiveness of the proposed method.