Residence time and the concentration of microorganism in the ozone contactor: a CFD simulation on chamber deflectors

Xiucheng Han,Xiaonan Zou,Jiajia Luo,Jiming Wu,Baoqing Deng
DOI: https://doi.org/10.1007/s11356-024-31909-x
IF: 5.8
2024-01-14
Environmental Science and Pollution Research
Abstract:Disinfection is an important step in deep drinking water treatment technology. This study applies computational fluid dynamics to investigate and optimize the hydrodynamics inside the ozone contactor. ANSYS Fluent was used to solve all the control equations. A step method is used to simulate the residence time distribution. The mean residence time is simulated under the Eulerian framework. The deflectors are installed in chambers to direct flow. The deflectors allow for a more uniform flow and a longer mean residence time within the contactor. The baffling factor showed that the deflectors could reduce the short-circuit effect in the contactor and improve the disinfection efficiency by 34.6% compared to the original reactor. The Morrill factor coefficient is improved by 22.8% compared to the original reactor. According to the Aral-Demirel index, contactors with deflectors are significantly better than other baffle-type contactors. The presence of the deflectors increased the microbial inactivation efficiency from 95.3 to 96.5%. The optimal deflector height should be controlled between 30 and 60 mm.
environmental sciences
What problem does this paper attempt to address?