Research on hysteresis control of capacitor's current of three-phase inverter

Xu Hai-fen
Abstract:The conventional hysteresis control strategy concentrates on the current of inductance.In this paper,a novel hysteresis control strategy concentrated on the current of capacitor was represented to improve the stability and dynamic response and restrain the non-linear load's disturbance of three-phase inverter.The outer-loop was the typical voltage feed-back control and the inner-loop was the represented capacitor's current hysteresis control.It is well known that the hysteresis controllers are intrinsically robust to system parameters,and exhibit very high dynamics.the model of the three-phase inverter was analyzed in this paper,and the current of capacitor hysteresis control strategy was introduced in detail.The simulation result indicates that this strategy is effective in restraining voltage distortion aroused by non-linear load.
Engineering
What problem does this paper attempt to address?