Stability Analysis and Mitigation of Oscillation in an Induction Machine
Kevin Lee,Wenxi Yao,Bin Chen,Zhengyu Lu,Anbo Yu,David Li
DOI: https://doi.org/10.1109/tia.2014.2320603
IF: 4.079
2014-01-01
IEEE Transactions on Industry Applications
Abstract:Open-loop constant voltage/frequency (v/f) adjustable speed drives (ASDs) can often experience undesirable sustained oscillations. Factors affecting these oscillation states include induction machine (IM) parameters, dead time, dc-link capacitor size, IM saturation, output voltage, carrier frequency, and IM speed. Many literatures have discussed the instabilities in light-load or low-frequency operating conditions. Quite a few methods have been proposed for stabilizing such a system. However, the instability problems, at different power levels, have not been completely described. This paper analyzes the causes of this instability for constant v/f drives as power levels change. The 2.2- and 15-kW low-voltage IMs and the 746-kW medium-voltage IM are evaluated to illustrate how the motor parameters affect the system stability. Additionally, a new oscillation mitigation method is introduced to demonstrate its effectiveness in solving the instability problems. It is based on the synchronous reference frame dynamic current feedback through its magnetic flux current component bandpass filtering and proportional control. In a theoretical stability analysis before and after the current feedback compensation, simulation studies are presented and verified through a 15-kW 380-V 50-Hz IM ASD experimental system.