Stability improvement control for metro traction drive system

Wen-li LIN,Zhi-gang LIU,Da-nan SUN,You-tong FANG
DOI: https://doi.org/10.3969/j.issn.1007-449X.2012.02.010
2012-01-01
Abstract:During the procedure of developing and testing metro traction drive system, the unstable phenomenon that current and voltage oscillations in AC and DC sides of traction inverter often occurs is found. To study the relationships between main circuit parameters and system stability, a small-signal equivalent circuit model for metro traction drive system was built in the nominal working zone, and the stability expressions were obtained. To eliminate the current oscillations in DC and AC sides and improve the system stability, two modules including oscillation eliminating and time-delay compensation were added in the traditional induction motor field oriented control strategy. The former actively increased the systematic damping, and the latter real-time regulated the motor rotor field position and completely decoupled d-q axis current. Both adopted the root locus method to perform the system stability analysis and verification. Finally, experiments were undertaken in Guangzhou metro line 1, and the effectiveness of the present control strategy is proved by the waveforms comparison.
What problem does this paper attempt to address?