Fusion Neutron-Induced Soft Errors During Long Pulse D-D Plasma Discharges in the WEST Tokamak

S. Moindjie,D. Munteanu,J. L. Autran,M. Dentan,P. Moreau,F. P. Pellissier,B. Santraine,J. Bucalossi,V. Malherbe,T. Thery,G. Gasiot,P. Roche,M. Cecchetto,R. Garcia Alia
DOI: https://doi.org/10.1109/tns.2023.3347673
IF: 1.703
2024-01-01
IEEE Transactions on Nuclear Science
Abstract:We have performed real-time soft error rate (SER) measurements on bulk 65 nm static random-access memories (SRAMs) during deuterium–deuterium (D-D) plasma operation at W–tungsten– Environment in Steady-state Tokamak (WEST). The present measurement campaign was characterized by the production of several tens of long pulse discharges (~60 s) and by a total neutron fluence (at the level of the circuits under test) up to ~109 n.cm-2, improving the error statistics by a factor of more than 6 with respect to the first measurements obtained in 2020. Experimental results demonstrate the occurrence of bursts of single-event upsets (SEUs) during the most efficient shots and 12% of multiple cell upset (MCU) events. Time-resolved data also show that MCUs are preferentially detected in the last part of these long pulses, providing further evidence that higher energy neutrons, initiated by deuterium–tritium (D-T) reactions due to triton burn-up in the D-D plasma, may play a role in the production of multiple cell upsets that cannot be attributed in such large proportions to “low energy” neutrons produced in D-D reactions.
engineering, electrical & electronic,nuclear science & technology
What problem does this paper attempt to address?