Coded excitation using TOP-CS sequences for multi-channel low-power ultrasonics

Connor Challinor,Neil Pearson,Frederic Cegla
DOI: https://doi.org/10.1016/j.ymssp.2024.111339
IF: 8.4
2024-05-01
Mechanical Systems and Signal Processing
Abstract:This paper presents a low-power hardware architecture that facilitates the simultaneous transmission and reception of ultrasonic signals when using coded excitations for ultrasonic measurements. With this architecture, long pseudo-periodic coded excitations, which have previously been unsuitable for pulse-echo measurements, can be used to produce high Signal-to-Noise Ratio (SNR) results without an increase in signal dead-zone and without introducing filter artefacts within a set measurement window. We show that a low-power system ( ± 2 V peak excitation amplitude without receiver amplification) utilising such coded excitations can achieve the same level of performance as a conventional high-power system ( − 200 V peak excitation amplitude with 15 dB receiver amplification) by producing 45 dB SNR measurements whilst maintaining a high Pulse Repetition Frequency (PRF) of ≥ 0.5 kHz. The use of pseudo-periodic sequences to produce quasi-orthogonal sequence families is then demonstrated to allow an arbitrary number of acquisition channels to be used simultaneously with complete crosstalk removal within a set measurement window. Therefore, the work presented here can open the door for the development of simplified low-power multi-channel acquisition systems without sacrificing system performance.
engineering, mechanical
What problem does this paper attempt to address?