Coded Excitation for Ultrasonic Testing: A Review

Chenxin Weng,Xu Gu,Haoran Jin
DOI: https://doi.org/10.3390/s24072167
IF: 3.9
2024-03-29
Sensors
Abstract:Originating in the early 20th century, ultrasonic testing has found increasingly extensive applications in medicine, industry, and materials science. Achieving both a high signal-to-noise ratio and high efficiency is crucial in ultrasonic testing. The former means an increase in imaging clarity as well as the detection depth, while the latter facilitates a faster refresh of the image. It is difficult to balance these two indicators with a conventional short pulse to excite the probe, so in general handling methods, these two factors have a trade-off. To solve the above problems, coded excitation (CE) can increase the pulse duration and offers great potential to improve the signal-to-noise ratio with equivalent or even higher efficiency. In this paper, we first review the fundamentals of CE, including signal modulation, signal transmission, signal reception, pulse compression, and optimization methods. Then, we introduce the application of CE in different areas of ultrasonic testing, with a focus on industrial bulk wave single-probe detection, industrial guided wave detection, industrial bulk wave phased array detection, and medical phased array imaging. Finally, we point out the advantages as well as a few future directions of CE.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to improve the signal - to - noise ratio (SNR) and imaging frame rate while ensuring resolution in ultrasonic testing. Traditional ultrasonic testing uses short - pulse excitation probes. Due to the low incident energy, insufficient SNR may occur when detecting highly sound - attenuating materials or deep - layer tissues in the human body. In order to increase the detection SNR, common methods such as increasing the pulse excitation voltage will affect the probe life, and may cause harm to the human body in medical ultrasonic testing; increasing the number of excitation oscillations will reduce the resolution; although using the averaging algorithm can improve the SNR, it will seriously affect the detection efficiency. Therefore, how to simultaneously improve the SNR and imaging efficiency without sacrificing resolution has become an urgent problem to be solved. Fortunately, the Coded Excitation (CE) technique provides a promising solution. CE increases the total emission energy by transmitting a modulated long - pulse without increasing the peak emission amplitude, and maintains the original axial resolution through the pulse - compression technique after receiving the signal, thereby enhancing the SNR. This method shows significant advantages in both industrial ultrasonic testing and medical ultrasonic testing.