Analysis on safe thickness of the horizontal separation pillar in the upward horizontal slicing and filling method
Xiu-Shan Qin,Hui Cao,Zhi-Xiu Wang,Zhi-Jie Zheng
DOI: https://doi.org/10.1088/1755-1315/861/5/052051
2021-10-01
IOP Conference Series: Earth and Environmental Science
Abstract:In the mines employing the upward horizontal slicing and filling mining method, it is necessary to set up a horizontal separation pillar in the middle transportation section. Too small a separation pillar may cause the roof to fall in the lower stope, damaging the transportation facilities in the middle section, and affecting the mining safety. Conversely, excessive thickness of the separation pillar will lead to the waste of mineral resources, reducing the economic benefits; therefore, the parameter optimization of horizontal separation pillar in the mining area remains a major safety and technical issue in upward horizontal slicing and filling mining. Taking the separation pillar in the middle section of an iron mine as the research object, various methods, including engineering analogy, theoretical calculation, and numerical simulation were used to comprehensively analyze the stability characteristics of the horizontal separation pillars with different thicknesses and determine the optimal thickness. For the stope with a span of 15–30 m mined with upward horizontal slicing and filling method in domestic and foreign mines, the thickness of horizontal separation pillar is 20–30 m, as analyzed using the engineering analogy method. Based on various theoretical formulas, such as the thickness-span ratio method, load transfer intersection line method, structural mechanics method, and others, the safety thickness of the separation pillar is calculated as 12–24 m with a safety factor of 1.50. According to a numerical calculation model established on the basis of measured drawings of stope and haulage roadways, the minimum safe thickness of the separation pillar is calculated as 23 m by the finite element analysis for typical sections. Based on the rock mass conditions and mining status of the iron mine, the thickness of horizontal separation pillar in the middle mining area is recommended to be no less than 23 m through a comprehensive analysis of empirical analogy, theoretical calculation, and simulation verification. The analysis results can provide a reference for the subsequent structural parameter adjustment and have a guiding significance for improving the comprehensive economic benefits of the mine.