Investigation on performance of a new thermoelectric cooler with hot and cold side separation for suppressing Fourier effect

Jinwen Yang,Chaoyang Mou,Jitian Han,Yi Ge,Wanchao Zhu,Wenxing Liang
DOI: https://doi.org/10.1016/j.enconman.2023.117760
IF: 10.4
2023-12-01
Energy Conversion and Management
Abstract:This paper proposed a new split structure of thermoelectric cooler to reduce the cold side temperature compared with the traditional thermoelectric cooler. A three-dimensional heat transfer model was established by COMSOL to explore the effect of the input current, the length and radius of the intermediate conductor, the heat dissipation condition and other parameters on performance of the new thermoelectric cooler. The results show that the split TEC element can continue to reduce the optimal cold side temperature by more than 30 K and the temperature difference between the cold and hot sides of the element can be doubled compared with the traditional element. The performance of the split element is affected by the length and radius of the intermediate conductor. There are different optimal intermediate conductor lengths and radii under different input current and heat dissipation conditions. In addition, compared with traditional elements, the split elements can continue cooling after the heat dissipation device on the hot side is completely damaged, thus effectively improving the reliability of elements. The temperature of cold side of split element can be further reduced under the pulse current.
energy & fuels,thermodynamics,mechanics