Exploitation of Digital Filters to Advance the Single-Phase T/4 Delay PLL System
Yongheng Yang,Keliang Zhou,Frede Blaabjerg
DOI: https://doi.org/10.1109/spec.2016.7846206
2016-01-01
Abstract:With the development of digital signal processing technologies, control and monitoring of power electronics conversion systems have been evolving to become fully digital. As the basic element in the design and analysis phases of digital controllers or filters, a number of unit delays (z -1 ) have been employed, e.g., in a cascaded structure. Practically, the number of unit delays is designed as an integer, which is related to the sampling frequency as well as the ac signal fundamental frequency (e.g., 50 Hz). More common, the sampling frequency is fixed during operation for simplicity and design. Hence, any disturbance in the ac signal will violate this design rule and it can become a major challenge for digital controllers. To deal with the above issue, this paper first exploits a virtual unit delay (z v - 1 ) to emulate the variable sampling behavior in practical digital signal processors with a fixed sampling rate. This exploitation is demonstrated on a T/4 Delay Phase Locked Loop (PLL) system for a single-phase grid-connected inverter. The T/4 Delay PLL requires to cascade 50 unit delays when implemented (for a 50-Hz system with 10 kHz sampling frequency). Furthermore, digital frequency adaptive comb filters are adopted to enhance the performance of the T/4 Delay PLL when the grid suffers from harmonics. Experimental results have confirmed the effectiveness of the digital filters for advanced control systems.