A Test of HTS Power Cable in a Sweeping Magnetic Field

H. Piekarz,S. Hays,J. Blowers,V. Shiltsev
DOI: https://doi.org/10.48550/arXiv.1201.5100
2012-01-24
Accelerator Physics
Abstract:Short sample HTS power cable composed of multiple 344C-2G strands and designed to energize a fast-cycling dipole magnet was exposed to a sweeping magnetic field in the (2-20) T/s rate. The B-field orientation toward the HTS strands wide surface was varied from 0 deg. to 10 deg., in steps of 1 deg.. The test arrangement allowed measurement of the combined hysteresis and eddy current power losses. For the validity of these measurements, the power losses of a short sample cable composed of multiple LTS wire strands were also performed to compare with the known data. The test arrangement of the power cable is described, and the test results are compared with the projections for the eddy and hysteresis power losses using the fine details of the test cable structures.
What problem does this paper attempt to address?