A Microfiber-Based Sensor for Simultaneous Measurement of Acetaminophen and Temperature

Yuting Bai,Yinping Miao,Hongmin Zhang,Chengwei Fei,Bin Li,Kailiang Zhang
DOI: https://doi.org/10.1109/jsen.2021.3097362
IF: 4.3
2021-09-15
IEEE Sensors Journal
Abstract:A fiber-optic sensor based on a microfiber coupler (MFC) for dual parameter detection of acetaminophen and temperature is proposed. The microfiber structure is manufactured by hydrogen-oxygen flame-heating technology. The characteristics of the transmission spectrum were studied theoretically and experimentally under conditions of different acetaminophen concentrations and temperatures. Acetaminophen concentration detection sensitivities of 102.4 pm/( <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="3.37ex" height="1.676ex" style="vertical-align: -0.338ex;" viewBox="0 -576.1 1451 721.6" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-6D" x="0" y="0"></use> <use xlink:href="#MJMATHI-75" x="878" y="0"></use></g></svg></span> mol/mL) and −0.01 dB/( <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="3.37ex" height="1.676ex" style="vertical-align: -0.338ex;" viewBox="0 -576.1 1451 721.6" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-6D" x="0" y="0"></use> <use xlink:href="#MJMATHI-75" x="878" y="0"></use></g></svg></span> mol/mL) in the range of 10 - <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="6.276ex" height="2.176ex" style="vertical-align: -0.338ex;" viewBox="0 -791.3 2702 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMAIN-35"></use> <use xlink:href="#MJMAIN-30" x="500" y="0"></use> <use xlink:href="#MJMATHI-6D" x="1251" y="0"></use> <use xlink:href="#MJMATHI-75" x="2129" y="0"></use></g></svg></span> mol/mL, as well as temperature sensitivities of −0.32 nm/°C and −0.001 dB/°C, were obtained for the proposed sensor. These results indicate that the photonic sensor has potential as a tool for pharmaceutical quality control and hospital wastewater treatment.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-6D" d="M21 287Q22 293 24 303T36 341T56 388T88 425T132 442T175 435T205 417T221 395T229 376L231 369Q231 367 232 367L243 378Q303 442 384 442Q401 442 415 440T441 433T460 423T475 411T485 398T493 385T497 373T500 364T502 357L510 367Q573 442 659 442Q713 442 746 415T780 336Q780 285 742 178T704 50Q705 36 709 31T724 26Q752 26 776 56T815 138Q818 149 821 151T837 153Q857 153 857 145Q857 144 853 130Q845 101 831 73T785 17T716 -10Q669 -10 648 17T627 73Q627 92 663 193T700 345Q700 404 656 404H651Q565 404 506 303L499 291L466 157Q433 26 428 16Q415 -11 385 -11Q372 -11 364 -4T353 8T350 18Q350 29 384 161L420 307Q423 322 423 345Q423 404 379 404H374Q288 404 229 303L222 291L189 157Q156 26 151 16Q138 -11 108 -11Q95 -11 87 -5T76 7T74 17Q74 30 112 181Q151 335 151 342Q154 357 154 369Q154 405 129 405Q107 405 92 377T69 316T57 280Q55 278 41 278H27Q21 284 21 287Z"></path><path stroke-width="1" id="MJMATHI-75" d="M21 287Q21 295 30 318T55 370T99 420T158 442Q204 442 227 417T250 358Q250 340 216 246T182 105Q182 62 196 45T238 27T291 44T328 78L339 95Q341 99 377 247Q407 367 413 387T427 416Q444 431 463 431Q480 431 488 421T496 402L420 84Q419 79 419 68Q419 43 426 35T447 26Q469 29 482 57T512 145Q514 153 532 153Q551 153 551 144Q550 139 549 130T540 98T523 55T498 17T462 -8Q454 -10 438 -10Q372 -10 347 46Q345 45 336 36T318 21T296 6T267 -6T233 -11Q189 -11 155 7Q103 38 103 113Q103 170 138 262T173 379Q173 380 173 381Q173 390 173 393T169 400T158 404H154Q131 404 112 385T82 344T65 302T57 280Q55 278 41 278H27Q21 284 21 287Z"></path><path stroke-width="1" id="MJMAIN-35" d="M164 157Q164 133 148 117T109 101H102Q148 22 224 22Q294 22 326 82Q345 115 345 210Q345 313 318 349Q292 382 260 382H254Q176 382 136 314Q132 307 129 306T114 304Q97 304 95 310Q93 314 93 485V614Q93 664 98 664Q100 666 102 666Q103 666 123 658T178 642T253 634Q324 634 389 662Q397 666 402 666Q410 666 410 648V635Q328 538 205 538Q174 538 149 544L139 546V374Q158 388 169 396T205 412T256 420Q337 420 393 355T449 201Q449 109 385 44T229 -22Q148 -22 99 32T50 154Q50 178 61 192T84 210T107 214Q132 214 148 197T164 157Z"></path><path stroke-width="1" id="MJMAIN-30" d="M96 585Q152 666 249 666Q297 666 345 640T423 548Q460 465 460 320Q460 165 417 83Q397 41 362 16T301 -15T250 -22Q224 -22 198 -16T137 16T82 83Q39 165 39 320Q39 494 96 585ZM321 597Q291 629 250 629Q208 629 178 597Q153 571 145 525T137 333Q137 175 145 125T181 46Q209 16 250 16Q290 16 318 46Q347 76 354 130T362 333Q362 478 354 524T321 597Z"></path></defs></svg>
engineering, electrical & electronic,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?