A modified approach for measuring the air permeability of ultra-high performance concrete (UHPC) under vacuum conditions

Mandip Dahal,Sungwoo Park,Sukhoon Pyo
DOI: https://doi.org/10.1016/j.conbuildmat.2023.132933
IF: 7.4
2023-08-16
Construction and Building Materials
Abstract:This study proposes a novel test method of the air permeability measurement under extreme vacuum condition to examine the performance of materials for Hyperloop tubes. Tests on cement-based materials demonstrated that the developed test setup was effective in measuring air permeability in extreme vacuum conditions. The results show that ultra-high performance concrete (UHPC) has significantly lower air permeability (10 –18 m 2 ) in vacuum conditions than other cement-based materials (10 –16 m 2 ) due to its dense microstructure and reduced pore size, which were within the range of previous results (10 -18 -10 -16 m 2 ). The measured porosity results had a strong correlation with air permeability (R 2 > 0.97), validating the suitability of the proposed method for measuring the air permeability of cement-based materials in vacuum conditions. These findings provide fundamental material properties for the design of Hyperloop tube structures.
construction & building technology,materials science, multidisciplinary,engineering, civil
What problem does this paper attempt to address?