A Sustainable Retrofit of an Industrial Heat Exchanger Network — A Case Study of a Gas Separation Plant in Thailand (HEN Retrofit on GSP)

Natchanon Angsutorn,Rungroj Chuvaree,Kitipat Siemanond
DOI: https://doi.org/10.1007/s41660-022-00280-0
2022-09-17
Process Integration and Optimization for Sustainability
Abstract:In this challenging work, sustainable heat integration using an industrial heat exchanger network (HEN) retrofit method by Angsutorn et al. (Chem Eng Sci 229:116005, 2021) was considered as a method for recovering waste energy to save heating and cooling utility costs of the gas separation plant Unit 5 (GSP5), a unit of the largest natural-gas separation company in Thailand. A high-energy-efficiency plant with a small heat recovery approach temperature (HRAT) of 7.5 °C, GSP5 is focused on the energy-efficiency improvement policy of the company. Our retrofit method consists of two nonlinear programming (NLP) optimization steps with the most practical retrofit concepts; installation of new heat exchanger units along with full utilization of all existing process heat exchangers without heat-transfer area modification and exchanger relocation. The retrofit design was generated at HRAT of 5.2 °C with a net present value (NPV) of $ 27,282,123 for a project life time of 20 years.Graphical Abstract
What problem does this paper attempt to address?