Micro-particle injection experiments in ADITYA-U tokamak using an inductively driven pellet injector
Sambaran Pahari,Rahulnath P.P,Aditya Nandan Savita,Pradeep Kumar Maurya,Saroj Kumar Jha,Neeraj Shiv,Raghavendra Mohan Kumar Kollipara,Harsh Hemani,Nagaraju Belli,Sukantam Mahar,Manmadha Rao,Suryaprasad V.V. Illa,U D Malshe,Joydeep Ghosh,Bharatkumar Ramaniklal Doshi,P K Chattopadhyay,R L Tanna,Kumarpalsinh A Jadeja,Kaushal Patel,Rohit Kumar,Tanmay Macwan,Harshita Raj,Suman Aich,Kaushlendra Singh,Suman Dolui,Devilal Kumawat,Moti Makwana,Kunal S Shah,Shivam Gupta,V Balakrishnan,C N Gupta,Swadesh Patnaik,Praveenlal E V,Minsha Shah,B Kadia,Nandini Yadava,Kajal Shah,Gaurav Shukla,Malay Bikas Chowdhuri,Ranjana Manchanda,Nilam Ramaiya,Manoj Kumar Gupta,Umesh Nagora,Varsha Siju,Surya Kumar Pathak,Kumudni Asudani,Paritosh Chaudhuri,P N Maya,Rajiv Goswami,Abhijit Sen,Y C Saxena,Rabindranath Pal,Shashank Chaturvedi
DOI: https://doi.org/10.1088/1741-4326/ad2b5f
IF: 3.3
2024-02-22
Nuclear Fusion
Abstract:A first-of-its-kind, Inductively driven micro-Particle (Pellet) accelerator and Injector (IPI) have been developed and operated successfully in ADITYA-U circular plasma operations, which may ably address the critical need for a suitable disruption control mechanism in ITER and future tokamak. The device combines the principles of electromagnetic induction, pulse power technology, impact, and fracture dynamics. It is designed to operate in a variety of environments, including atmospheric pressure and ultra-high vacuum. It can also accommodate a wide range of pellet quantities, sizes, and materials and can adjust the pellets' velocities over a coarse and fine range. The device has a modular design such that the maximum velocity can be increased by increasing the number of modules. A cluster of Lithium Titanate/Carbonate (Li2TiO3/Li2CO3) impurity particles with variable particle sizes, weighing ~ 50 – 200 mg are injected with velocities of the order of ~ 200 m/s during the current plateau in ADITYA-U tokamak. This leads to a complete collapse of the plasma current within ~ 5 – 6 ms of triggering the injector. The current quench time is dependent on the amount of impurity injected as well as the compound, with Li2TiO3 injection causing a faster current quench than Li2CO3 injection, as more power is radiated in the case of Li2TiO3. The increase in radiation due to the macro-particle injection starts in the plasma core, while the Soft X-ray emission indicates that the entire plasma core collapses at once.
physics, fluids & plasmas