Characteristic Research of Pellet Injection System in KSTAR

SooHwan Park,HongTack Kim,JaeIn Song,InSik Woo,KunSu Lee,HyunMyung Lee,YoungOk Kim,Hirofumi Yonekawa,KwangPyo Kim,Yong Chu,YeongKook Oh
DOI: https://doi.org/10.1016/j.fusengdes.2018.04.076
IF: 1.905
2018-01-01
Fusion Engineering and Design
Abstract:20 Hz pellet injection system was installed for improving a fueling system of KSTAR (Korea Superconducting Tokamak Advanced Research) in 2016. Several things of hardware such as a liquid helium transfer line, an extruder nozzle and an extension part of pellet guide tube are changed for 2017 campaign. For plasma experiments, the pellet injection system uses the smallest pellet (1.5 mm of length, 2 mm of diameter). The pellet velocity can be variable from 150 m/s to over 200 m/s by controlling of propellant gas pressure. The clear increase of plasma density observed during KSTAR experiments is also presented in this paper.
What problem does this paper attempt to address?