In vivo osseointegration evaluation of implants coated with nanostructured hydroxyapatite in low density bone

Daniel Almeida,Suelen Cristina Sartoretto,Jose de Albuquerque Calasans-Maia,Bruna Ghiraldini,Fabio Jose Barbosa Bezerra,Jose Mauro Granjeiro,Mônica Diuana Calasans-Maia
DOI: https://doi.org/10.1371/journal.pone.0282067
IF: 3.7
2023-02-24
PLoS ONE
Abstract:This in vivo study, aimed to biomechanically, histomorphometrically and histologically evaluate an implant surface coated with nanostructured hydroxyapatite using the wet chemical process (biomimetic deposition of calcium phosphate coating) when compared to a dual acid-etching surface. Ten sheep (2–4 years old) received 20 implants, 10 with nanostructured hydroxyapatite coating (HAnano), and 10 with dual acid-etching surface (DAA). The surfaces were characterized with scanning electron microscopy and energy dispersive spectroscopy; insertion torque values and resonance frequency analysis were measured to evaluate the primary stability of the implants. Bone-implant contact (BIC) and bone area fraction occupancy (BAFo) were evaluated 14 and 28 days after implant installation. The HAnano and DAA groups showed no significant difference in insertion torque and resonance frequency analysis. The BIC and BAFo values increased significantly (p<0.05) over the experimental periods in both groups. This event was also observed in BIC value of HAnano group. The HAnano surface showed superior results compared to DAA after 28 days (BAFo, p = 0.007; BIC, p = 0.01). The results suggest that the HAnano surface favors bone formation when compared to the DAA surface after 28 days in low-density bone in sheep.
multidisciplinary sciences
What problem does this paper attempt to address?